7. STOPLIGHT(S) DO NOT OPERATE.
INITIAL SETUP
Personnel Required
Tools and Special Tools
Two
Tool Kit, General Mechanic's: Automotive
(Item 18, Appendix F)
References
STE/ICE-R (Item 17, Appendix F)
TM 10-3930-673-10
Multimeter, Digital (Item 9, Appendix F)
TM 9-4910-571-12&P
Equipment Condition
Engine shut down (TM 10-3930-673-10)
Parking brake on (TM 10-3930-673-10)
Wheels chocked (TM 10-3930-673-10)
START
1
KNOWN INFO
TEST OPTIONS
None.
Continuity test.
Is continuity present on faulty
STE/ICE-R #88.
POSSIBLE PROBLEMS
stoplight?
REASON FOR QUESTION
Bulb(s) faulty.
Socket(s) faulty.
If continuity is not present, replace
Wire 43 faulty.
bulb(s).
Connector P1 faulty.
Connector J1 faulty.
Blackout light switch faulty.
Wire 42 faulty.
Brake switch faulty.
Wire 41 faulty.
Wire 40 faulty.
Circuit breaker CB4 faulty.
Wire 3 faulty.
Replace faulty bulb
NO
Run relay faulty.
(Para 8-33).
Wire 1 faulty
Circuit breaker CB6 faulty.
Wire 9 faulty.
YES
Connector P2 faulty.
Connector J2 faulty.