2
1. 24 VDC CIRCUITS DO NOT OPERATE.
INITIAL SETUP
Personnel Required
Tools and Special Tools
Two
Tool Kit, General Mechanic's: Automotive
(Item 18, Appendix F)
References
STE/ICE-R (Item 17, Appendix F)
TM 10-3930-673-10
Multimeter, Digital (Item 9, Appendix F)
TM 9-4910-571-12&P
Equipment Condition
Engine shut down (TM 10-3930-673-10)
Parking brake on (TM 10-3930-673-10)
Wheels chocked (TM 10-3930-673-10)
START
WARNING
1
KNOWN INFO
TEST OPTIONS
Read WARNING on
None.
Check connections.
following page.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Are battery connections loose
Battery connections faulty.
This question eliminates possible
Battery faulty.
problems and determines where
or corroded?
Battery cable faulty.
troubleshooting continues.
Wire 9 faulty.
Connector P2 faulty.
Connector J2 faulty.
Circuit breaker CB6 faulty.
Ground faulty.
Go to Step 2 of this
NO
fault.
YES
Clean and tighten
cable connections
(Para 8-42).