TM 10-3930-673-20-1
Table 2-1. Unit Preventive Maintenance Checks and Services (Continued)
Location
Item
Item to Check/
No.
Interval
Service
Procedure
9
Daily
Batteries
WARNING
Do not smoke or allow any flame or spark in the vicinity while
checking or filling the batteries. The batteries generate
hydrogen gas, a highly explosive gas. Severe personal injury
could result.
Daily
Test batteries to determine cell condition. Replace or add electrolyte
(if necessary) and recharge. Refer to TM 9-6l40-200-l4.
10
Service Brakes
TR00922
Weekly
Lubricate brake pedal and transmission disconnect pedal countershaft
with GAA as required. Lubrication points are under cab.
Quarterly
Check brake pads for wear. Pads should not be allowed to wear below
1/8 inch in thickness. Refer to Para 12-5 for wear pad replacement
procedures.
Quarterly
Check brake rotors for grooves, discoloration, cracks, and warpage.
|