TM 10-3930-673-20-1
2
Table 2-1. Unit Preventive Maintenance Checks and Services
Location
Item
Item to Check/
No.
Interval
Service
Procedure
CAUTION
The following new vehicle (break-in) maintenance is required
on the ATLAS to prevent damage to the equipment and
maintain the warranty.
THE FOLLOWING ITEMS MUST BE CHANGED AFTER THE
FIRST 20 HOURS OF OPERATION:
Transmission oil and transmission oil filter element (refer to Para
9-6).
THE FOLLOWING ITEMS MUST BE CHANGED AFTER THE
FIRST 50 HOURS OF OPERATION:
Planetary gear oil (refer to Para 11-3).
Differential oil (refer to Para 11-2).
Hydraulic oil filter element (refer to Para 18-27).
Engine oil and engine oil filter element (refer to Para 4-2).
THE FOLLOWING ITEMS MUST BE CHECKED AND
ADJUSTED IF NECESSARY AFTER THE FIRST 100 HOURS OF
OPERATION:
Boom electrical cable tension (refer to Para 18-24).
Boom hydraulic hose tension (refer to Para 18-24).