TM 10-3930-660-24-2
BOOM ELECTRICAL CABLE REPLACEMENT - CONTINUED
0233 00
REMOVAL - CONTINUED
6.
Disconnect electrical lead (9) on terminal strip (10) by
12
loosening screw (11).
9,10,11
13
7.
To remove boom electrical cable (12), cut two tie
14
straps (13) where cable (12) enters electrical box (3).
Discard tie straps.
8.
Carefully pull cable (12) from electrical box (3).
3
409-422
9.
Remove nut (15), lockwasher (16) and flatwasher (17)
securing clamp (18) and cable (12) to MLRS attach-
ment. Discard lockwasher.
12
17 18
15
16
409-423
10.
Loosen two jamnuts (19) and two capscrews (20) at
21
hose tensioner (21) to release tension on boom electri-
cal cable (12).
19
20
12
409-1732
0233 00-2
|