8.
Remove nut (11), lockwasher (12), washer (13) and
clamp (14). Move hoses (15) out of the way. Discard
lockwasher.
9.
Carefully pull cable (3) from box (2).
10.
Secure cover (5) to box (2) by tightening four screws
11,12,
(4).
13,14
11.
Support MLRS attachment (16) using lifting device.
25
15
WARNING
Use caution when handling heavy parts.
Provide adequate support and use assis-
tance during procedure. Ensure that any
lifting device used is in good condition
and of suitable load capacity. Keep clear of
heavy parts supported only by lifting
device. Failure to follow this warning may
cause injury or death.
NOTE
16
17,18,19,20
MLRS attachment weighs approximately
2,500 lb (1134 kg) when all components,
23
including forks, remain installed.
Place container under disconnected hoses to
catch hydraulic oil.
12.
Remove bolt (17), lockwasher (18), clamp (19) and
lockwasher (20) securing each hose (21) to each end-
plate (22). Discard lockwashers.
22
24
13.
Disconnect two hoses (21) from two elbows (23) on
21
cylinder (24).
14.
Disconnect three hydraulic hoses (15) from boom fit-
409-4045
tings (25) at front of boom. Cap open boom fittings
with metal caps.