Click here to make tpub.com your Home Page

Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-660-24-1
MLRS ATTACHMENT CONTROL VALVE ASSEMBLY REPLACEMENT - CONTINUED
0176 00
INSTALLATION - CONTINUED
10.
Connect two crossover hoses (7) to carriage tilt cylin-
3,4
der fittings (8) as tagged.
11.
Position cover (6) over valve and align mounting
6
holes.
12.
Apply loctite to two capscrews (3) and two nuts (5).
5
13.
Secure cover (6) with two nuts (5), two capscrews (3)
and two new lockwashers (4).
14.
Connect floodlight electrical leads (1) and (2) as
1,2
tagged.
409-668
NOTE
White lead of floodlight connects to lead 71 of vehicle wiring harness. Black lead of floodlight connects to
lead 02 of vehicle wiring harness.
15.
Connect battery cables (WP 0107 00).
16.
Purge air from hydraulic system by cycling each MLRS attachment function five times (TM 10-3930-660-10).
NOTE
Excessive air in hydraulic system may temporarily prevent MLRS attachment functions from operating.
Attempt to operate MLRS attachment functions as required until each function operates smoothly and com-
pletely (TM 10-3930-660-10).
END OF WORK PACKAGE
0176 00-4

Privacy Statement - Press Release - Copyright Information. - Contact Us