TM 10-3930-660-24-1
MLRS ATTACHMENT CONTROL VALVE ASSEMBLY REPLACEMENT - CONTINUED
0176 00
REMOVAL
1.
Disconnect floodlight electrical leads (1 and 2) at
plugs.
2.
Remove two capscrews (3), two lockwashers (4) and
two nuts (5) that secure attachment valve cover (6).
Discard lockwashers.
3.
Remove attachment cover (6).
3,4
6
5
1,2
409-663
4.
Tag both crossover hoses (7).
9,10
5.
Disconnect and remove crossover hoses (7) at fittings
(8).
6.
Disconnect eleven hydraulic hoses (9) at fittings (10)
and remove from valve.
8
7
9
409-664
0176 00-2
|