TM 10-3930-660-24-1
MAIN CONTROL VALVE MAINTENANCE - CONTINUED
0175 00
NOTE
Tag all electrical connections before removing for use during installation.
If more than one hydraulic line is to be removed, tag and identify lines to assure proper installation. Use con-
tainer to catch any hydraulic oil that may drain from system.
REMOVAL
1.
Disconnect thirteen hydraulic hoses (1) and one tube
(2) at fittings (3).
2.
Cap hydraulic hose and tube fittings (3).
1
3
3
2
3
1
409-653
NOTE
Main control valve weighs 60 lb (27 kg). When performing the following procedure, grasp the valve so it
does not drop when fasteners are removed.
3.
Remove three nuts (4), three lockwashers (5) and three capscrews (6) that secure valve. Discard lockwashers.
4.
Remove control valve (7).
0175 00-2
|