TM 10-3930-660-24-1
HYDRAULIC BYPASS SWITCH MAINTENANCE - CONTINUED
0091 00
TESTING - CONTINUED
NOTE
If voltage requirements are not met in steps 11 thru 18, perform continuity tests in step 19 of this section.
19.
Perform continuity tests on hydraulic bypass switch (1).
NOTE
Tag all electrical leads as removed.
20.
Remove electrical lead 91 from terminal of switch (1).
21.
Remove electrical lead 10 from terminal of switch (1).
22.
Connect positive lead of ohmmeter to terminal of switch (1).
23.
Connect negative lead of ohmmeter to other terminal of switch (1).
24.
Ohmmeter should indicate continuity.
25.
Start engine (TM 10-3930-660-10).
26.
Ohmmeter should indicate no continuity.
27.
Stop engine (TM 10-3930-660-10).
NOTE
If continuity requirements are not met in steps 20 thru 27, hydraulic bypass switch is defective and must be
replaced. Refer to Removal and Installation.
28.
Disconnect leads of ohmmeter from terminals of switch (1).
29.
Connect electrical lead 10 to terminal of switch (1).
30.
Connect electrical lead 91 to other terminal of switch (1).
END OF WORK PACKAGE
0091 00-5
|