TM 10-3930-660-24-1
BOOM ELECTRICAL JUNCTION BOX ASSEMBLY REPLACEMENT - CONTINUED
0085 00
INSTALLATION - CONTINUED
12.
Place cover (6) on boom electrical box (1) and secure
1
by tightening four screws (5).
5
13.
Insert plug on auto leveler cable (3) into connector (4)
6
at boom electrical box (1). Twist collar (2) until auto
leveler cable (3) is secure.
14.
Connect battery cables (WP 0107 00).
3
2,4
409-336
15.
Check all MLRS attachment and fork auto leveler functions for proper operation (TM 10-3930-660-10).
END OF WORK PACKAGE