TM 10-3930-660-24-1
TOGGLE AND PUSHBUTTON SWITCHES REPLACEMENT - CONTINUED
0069 00
INSTALLATION - CONTINUED
4.
Secure switch (4) at face of instrument panel (8) with nut and rubber cover assembly (7).
5.
Connect electrical leads (2) to switch (4) as tagged.
6.
For switches with screw-type terminals, position elec-
5
trical leads (2) on terminals (6) of switch (4) as tagged,
and secure with screws (5).
2
7.
For switches with spade-type terminals, push female
connectors (1) of electrical leads (2) on male terminals
(3) of switches (4) as tagged.
4
6
1 3
2
409-270
8.
Install left and/or right-hand instrument panel, as required (WP 0067 00).
END OF WORK PACKAGE