COOLANT OVERFLOW TANK REPLACEMENT - CONTINUED
0054 00
INSTALLATION - CONTINUED
NOTE
A 50-50 mixture of ethylene glycol and clean water is used in the 6K Forklift. Use of plain water coolant is
not recommended. Never add coolant without first diluting to a 50-50 mixture.
4.
To fill overflow tank (1), open overflow tank cap (7).
5.
Add 2 qts of coolant to overflow tank (1).
6.
Close overflow tank cap (7).
7.
Slowly remove radiator cap (8) and allow pressure to
escape.
8.
Add coolant to radiator (9) as necessary, until coolant
level reaches bottom of filler neck.
9.
Install radiator cap (8).
10.
Start engine and check for leaks (TM 10-3930-660-
10).
8
9
7
1
409-4022
END OF WORK PACKAGE