Click here to make tpub.com your Home Page

Page Title: ETHER START HOSE AND ATOMIZER REPLACEMENT
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-660-24-1
ETHER START HOSE AND ATOMIZER REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool kit, general mechanic's (Item 39, WP 0324 00)
Vehicle parked on level ground (TM 10-3930-660-
10)
Ether start cartridge removed (WP 0045 00)
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke and make sure you are in a well-ventilated
area away from heat, open flames or sparks. Wear eye protection. Avoid contact with skin and eyes and
avoid breathing ether fumes. If fluid enters or fumes irritate the eyes, wash immediately with large quantities
of clean water for 15 minutes. Seek medical attention immediately if ether is inhaled or causes eye irritation.
Failure to follow this warning may cause injury or death.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business