TM 10-3930-660-24-1
AIR CLEANER ASSEMBLY MAINTENANCE - CONTINUED
0024 00
ASSEMBLY
27
1.
Install baffle (35) to access cover (27) and tighten cap-
tive wingnut (34).
35
17
2.
Install vacuum diaphragm (33) to access cover (27).
32
3.
Install and tighten two clamps (17) to housing (5).
5
4.
Install O-ring (32) to housing (5).
25
34
33
409-166
28
5.
Position secondary filter element (31) in housing (5)
29
and secure with wingnut (30).
6.
Position primary filter element (29) in housing (5) and
30
secure with wingnut (28).
31
7.
Position access cover (27) on housing (5) and secure
with clamp (26).
5
27
26
409-172
8.
Reset air intake restriction indicator (TM 10-3930-660-10).