TM 10-3930-660-24-1
AIR CLEANER ASSEMBLY MAINTENANCE - CONTINUED
0024 00
DISASSEMBLY
1.
Loosen clamp (26) securing access cover (27) to hous-
ing (5).
2.
Remove wingnut (28) and primary filter element (29)
from housing (5).
3.
Remove wingnut (30) and secondary filter element
(31) from housing (5).
28
29
30
31
5
27
26
409-160
27
4.
Remove O-ring (32) from housing (5).
35
5.
Loosen and remove two clamps (17) from housing (5).
17
6.
Remove vacuum diaphragm (33) from access cover
32
(27).
5
7.
Loosen captive wingnut (34) and remove baffle (35)
25
34
from access cover (27).
33
CLEANING
Refer to Cleaning Instructions (WP 0316 00).
409-166
INSPECTION
Refer to Inspection Instructions (WP 0317 00).
0024 00-5
|