TM 10-3930-660-24-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 17. Braking System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for seal damage in
Repair brake control valve (WP
6.
Brake Accumulator Charges Frequently
brake control valve.
While Brakes Are Being Held.
0299 00).
2. Check for seal damage on
Repair brake control valve (WP
piston in brake control valve.
0299 00).
Check for seal damage in brake
Repair brake control valve (WP
7.
Brake Accumulator Starts to Charge But
Does Not Reach High Limit.
control valve.
0299 00).
1. Check for broken spring in
Repair brake control valve (WP
8.
Brake Accumulator Charging Time Too
brake control valve.
Long.
0299 00).
2. Check for dirt in filter of
Repair brake control valve (WP
brake control valve.
0299 00).
3. Check for sticking poppet in
Repair brake control valve (WP
brake control valve.
0299 00).
1. Check for broken springs in
Repair brake control valve (WP
9.
Brake Accumulator Fails to Start Charging.
brake control valve.
0299 00).
2. Check for seal damage in
Repair brake control valve (WP
brake control valve.
0299 00).
3. Check for dirt in filter of
Repair brake control valve (WP
brake control valve.
0299 00).
Check for pilot valve for wear in
Repair brake control valve (WP
10. Very Rapid Cycling of Brake Valve.
brake control valve.
0299 00).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |