STEP 25. Check the sealing rings on the input
shaft. Rings must be replaced if a MAXIMUM of
.008 wear and above exists.
Step 25. Plate 10352
STEP 27. Lock ring by holding one end of the
STEP 26. Install the sealing rings by starting
split lock and roll the ring down into groove
the split locks first and pressing the ring down
until one lock is above the other and press down
and on . . . . this will prevent the ring from
o n top lock until ring locks....this will pre-
becomming warped or broken.
vent breakage of the locking tangs.
Step 27. Plate 10354
Step 26. Plate 10353
5-80U
|