Click here to make tpub.com your Home Page

Page Title: DISASSEMBLY
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

IMPORTANT: Read the introductory paragraphs on 5-50B
before proceeding with either one of these sections.
UNDERCHARGED ENERGIZER
OVERCHARGED ENERGIZER
This condition, as evidenced by slow cranking and law
1. connect a voltmeter fron alternator No. 2 term-
specific gravity readings, can be caused by one or
inal to ground.  If reading is zero, No. 2 lead
more of the following conditions even though the in-
circuit is open.
dicator lamp may be operating normally. The follow-
ing procedure also applies to circuits with an am
2.
If Energizer and No. 2 lead circuit check good, but
meter.
a" obvious overcharge condition exists as evidenced
by excessive Energizer water usage, proceed as follows:
1. Insure that the undercharged contion has not
a. Separate end frames as covered in "Disassembly"
been caused by accessories having bee" left
section under heading of "ALTERNATOR REPAIR". Check
on for extended periods.
field winding for shorts.  If shorted replace rotor
2. Check the drive belt for porper tension.
and regulator.
3.
b. Connect ohmmeter using lowest range scale
Inspect the wiring for defects. Check all connec-
from brush lead clip to end frame as shown in
tions for tightness and cleanliness, Including the
Step 1, Figure 8, then reverse lead connections.
slip connectors at the alternator and firewall, and
the cable clamps and battery posts.
c.  If both readings are zero, either the brush lead
clip is grounded or regulator is defective
4. With ignition switch on connect a voltmeter from:
a. Alternator "BAT" terminal to ground
d. A grounded brush lead clip can result from
b. Alternator No. 1 terminal to ground
omission of insulating washer (Fig. 8), omission
c. Alternator No. 2 terminal to ground
of lnsulating sleeve over screw, or damaged in-
sulating sleeve. Remove screw to inspect sleeve
A zero reading indicates an open between volt-
If satisfactory, replace regulator as covered
meter connection and Energizer.
under heading of "ALTERNATOR REPAIR".
5. If previous Steps 1 through 4 check satisfactorily,
check Delcotron alternator as follows:
a. Disconnect Energizer ground cable.
b. Connect an ammeter in the circuit at the "BAT"
terminal of the alternator,
c. Reconnect Energizer ground cable.
d. Fully load electrical circuit. and connect a
carbon pile across the Energizer.
e. Operate enqine at moderate speed as required,
and adjust carbon pile as required. to obtain
maximum current output.
If ampere output is not within 10 percent of rated
If ampere output is within 10 percent of rated output
output, ground the field winding by inserting a screw-
as stamped on alternator frame, alternator is not de-
driver into the test hole (Fig. 6). CAUTION: Tab is
fective; recheck Steps 1 thru 5.
within 3/4 inch of casting surface. Do not force screw-
driver deeper than one inch into end frame.
Operate engine at moderate speed as required, and
adjust carbon pile as required to obtain maximum
current output.
If output iS not within 10 percent of rated output,
If output is within 10 percent of rated output. re-
check the field winding, diode, trio, rcctifier bridge,
place regulator as covered in ALTERNATOR REPAIR"
and stator as covered in "ALTERNATOR REPAIR" section.
section, and check field winging.
5-50C

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business