TM 10-3930-638-24&P
3-30. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
d. Rotation Cylinder Assembly (cont).
ITEM
ACTION
REMARKS
LOCATION
STEP
DISASSEMBLY
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors, Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
Use cleaning solvent P-D-680
Clean all exterior
Rotation
a. Rotation cylinder
2
surfaces
assembly (8)
cylinder
Remove
assembly (8)
b. Two lubrication
fittings (9)
Loosen
c. Gland assembly (17)
Remove as an
d. Rod (24), gland as-
sembly (17), and
assembly
piston assembly (12)
Remove
e. Cap screw (10) and
washer (11)
f. Piston assembly (12)
Remove
Remove
g. Gland assembly (17)
Remove and
3
Piston assembly
a. Wear ring (13)
(12)
discard
Remove and
b. Sealing ring (14)
discard
c. O-ring (15)
Remove and
discard
4
Remove only if
a. Plug (18)
Gland assembly
(17)
damaged
Remove and
b. O-ring (19)
discard
c. Back-up ring (20)
Remove and
discard
d. Wiper(21)
Remove and
discard
e. Seal (22)
Remove and
discard