TM 10-3930-638-24&P
3-14. INSTRUMENT PANEL REPLACEMENT (cont)
REMARKS
ITEM
ACTION
STEP
LOCATION
REMOVAL
Loosen and
a. Four nuts (1), lock
1
Operator's
remove
washers (2) and
compartment
washers (3)
Lift and
b. Four cap screws
remove
(4)
Use sling and hoist
c. Instrument panel
Lift and
remove
(5)
WARNING
CLEANING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
con tact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
Wear safety glasses when drying parts with compressed air. Fail-
ure to do so could cause serious injury to eyes and possible blind-
ness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.
2
All parts
Clean
Use cleaning solvent P-D-680. Dry thor-
oughly with compressed air
INSPECTION
3
Nuts (1), washers (2
Inspect
Replace if worn, or if threads damaged
and 3) and cap
screws (4)
4
Inspect
Instrument panel (5)
Repair broken welds or cracks by welding.
Replace if severely cracked or damaged
INSTALLATION
Position
5
a. Instrument
In operator's compartment, with frame
Operator's
and instrument panel mounting holes
panel (5)
compartment
aligned
Install and
b. Four cap screws (4)
Until instrument panel is securely mounted
tighten
washers (3), lock
washers (2) and
nuts (1)