TM 10-3930-638-10
3-5. TROUBLESHOOTING TABLE (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. ENGINE WILL NOT CRANK (cont)
Lower tow bar, open grille, and remove battery cover as described in step 3 above.
Step 5.
WARNING
Battery electrolyte is toxic and corrosive. Use protective goggles and gloves when performing the
following. Avoid contact with skin, eyes, clothes, and don't breathe vapors.
Using a hydrometer and thermometer, check specific gravity of battery electrolyte in each cell.
Refer to following figure:
To determine charge of a battery, hydrometer readings must be corrected to a temperature of
80 degrees F. The normal correction is 4 points (0.004) of gravity for each 10 degrees change in
temperature above or below 80 degrees. Example: If the specific gravity reading is 1,280 at zero
degree F, subtract 0.032 as shown in the figure below. The corrected reading in this case
is 1,248.
Notify organizational maintenance if a corrected specific gravity reading of less than 1.225 is
obtained (battery must be recharged) or if specific gravity reading between cells differs by more
than 25 points (0.025) (battery must be replaced).
3-5
|