Table 4-1. Unit Preventive Maintenance Checks and Services Model MLT 6-2
Location
Not Fully Mission
Item
Interval
Item To
Procedure
Capable If:
No.
Check
Service
Engine
Belts are worn excessively
Check for excessive wear, darnage, and
4
Quarterly
Drive
or damaged
proper tension (1/2 inch to 3/4 inch de-
Belt
flection with about 10 lbs applied force
midway between the pulleys).
WARNING
Low pressure air used for cleaning
purposes will not exceed 30b psi.
Effective chip guarding and per-
sonal protective equipment (gog-
gles/shield, gloves, etc.) will be
used.
If NBC exposure is suspected, all
air filter media will be handled by
personnel wearing full NBC pro-
tective equipment.
Clean air cleaner filter with low pressure
Quarterly
Air
5
air by blowing from the inside out (Ref
Cleaner
para 3-8). Reset contamination indicator.
Filter
a. Clean primary fuel filter
Quarterly
Fuel
6
Filter
b. Replace secondary fuel filter
Change 1