Figure 2-8. Static panel.
(c) Remove screws securing static panel to
(d) Secure door in position with screws and lock
door from beneath door.
washers.
(d) Carefully remove static panel from door.
(2) Contactor panel.
b. Installation.
(a) Install contactor panel in position on truck
frame. Secure panel to truck frame with screws, lock
(1) Static panel.
washers and nuts.
(a) Install static panel (fig. 2-8) on access door
(b) Connect cables to posts on lower surface of
and secure with screws inserted through door.
contactor box.
(b) Connect wiring harness plug to static panel
(c) Connect two plugs to wiring harness.
plug. Connect cables to correct posts on terminal block.
(d) Install sheet metal cover on contactor box.
(c) Carefully lift door up and into position on
(e) Refer to TM10-3930-631-12 and install
frame. Be careful not to pinch wires and cables when
battery.
closing door.