Malfunction
Probable cause
Corrective Action
10. Excessive play in steering
Loose nut or housing bearing.
Refer to para 4-40.
wheel.
11. Accelerator pedal does not
Refer to direct and general support
return.
maintenance personnel.
a. Bulb burned out.
a. Replace (para 4-18).
12. Stoplight does not work.
b. Other causes.
b. Refer other causes to direct and
general support maintenance
personnel.
a. Mast slides dry.
a. Lubricate para 3-2.
13. Lift descends too slowly without
load.
b. Other causes.
1. Refer other causes to direct and
general support maintenance
personnel.
14. Lift descends too fast with load.
Refer to direct and general support
maintenance personnel.
a. No voltage.
a. Check that battery connector latch is
15. Horn does not blow.
engaged. Use voltmeter or test
lamp to check circuit.
b. Fuse blown.
b. Replace fuse.
c. Defective horn.
c. Replace horn.
d. Other causes.
d. Refer to direct and general
support personnel.
Section VII. MAINTENANCE OF ELECTRICAL SYSTEM
for organizational maintenance. Always disconnect the
4-13. General
battery connector before working on electrical parts.
The electrical system contains the hour meter, light
4-14. Hour Meter
switch, emergency stop switch, stoplight switch, lamps,
a. Removal. Refer to figures 4-2 and 2-1.
resistors, horn, batteries, wiring harness and their
component parts. Paragraphs 4-14 through 4-25 contain
(1) Tag and disconnect the electrical leads
adjustment, removal, disassembly, cleaning, inspection,
as necessary.
repair, assembly and installation instructions as required
(2) Remove the three attaching screws,
lockwashers and nuts.
4-6
|