CHAPTER 5
MATERIAL USED IN CONJUNCTION WITH THE TRUCK
5-1. General
5-2. Operating Extinguisher
This section contains instructions for operating the
a. Disconnect the clamp that secures the
portable fire extinguisher (fig. 5-1) that is supplied with
extinguisher to its mounting bracket, swing the clamp
the truck. The dry chemical type fire extinguisher is
open, and remove the extinguisher.
suitable for use on all types of fire and is effective in
b. Hold the extinguisher upright and raise the
areas where ambient, temperature is 250F and above.
locking handle to break the seal.
The fire extinguisher is a 2 pound, stored pressure,
c. Aim the nozzle at the base of the fire and
lever operated extinguisher.
depress the small operating lever with the thumb.
d. Direct the discharge at the base of the fire with
a side-to-side sweeping motion.
Note. This fire extinguisher can be used on
flammable liquid and electrical fires.
5-3. Maintenance
a. Check the fire extinguisher thoroughly to assure
that it is in good condition and ready for operation.
b. Check that the discharge nozzle is not dented or
obstructed.
c. Check the pressure gage to assure that it is at or
above the FULL mark.
d. If the pressure gage indicates less than full, the
extinguisher must be replaced.
Warning: Do not attempt to recharge the
extinguisher. It must be recharged by replacing
with a new, factory charged cylinder.
Figure 5-1. Fire extinguisher.