TM 10-3930-623-12
shown in wiring diagram, figure 1-11. Observe all
3.
Voltage Adjustment.
To adjust the voltage
precautions given in paragraph 5-35 to prevent damage
regulator setting, remove the access plug from the
to diodes and windings.
regulator. Then for an undercharged battery insert
screwdriver into slot and turn clockwise one notch (0.3
5-36.
SETTING
VOLTAGE
REGULATOR
TO
volt) to increase the setting. For an overcharged battery,
BATTERY NEEDS.
turn counterclockwise one notch (0.3 volt) to decrease
setting. Then check for an improved battery condition
1. The desired voltage regulator setting is one which
keeps the battery in a satisfactory state of charge (3/4
over a service period of reasonable length. If necessary,
charge or more) without causing excessive battery
repeat the above procedure for a higher or lower setting.
overcharge (as evidenced by excessive battery water
usage). However, if operating service conditions are
4. Removal.
above or below average, the voltage regulator setting
must be adjusted or tailored to adapt it to the battery and
a. Disconnect negative battery cable from battery
type of service conditions. Either of two conditions may
persistently exist which indicate the need for adjusting
post (para 6-47).
the regulator setting: either battery is being overcharged,
or battery remains undercharged. Corrections should be
b. Tag and disconnect alternator and battery leads
made as follows:
at the voltage regulator (fig. 6-3 ).
a. If the battery uses too much water at the normal
c. Remove capscrews and lockwashers that
setting, reduce the voltage setting approximately 0.3 volt
secure the regulator to the mounting bracket and remove
and check for decreased battery water usage over a
reasonable period. If necessary, repeat this process
regulator.
until the battery remains charged with a minimum use of
water.
5. Installation. Reverse removal procedure and install
the voltage regulator.
b. If the battery is consistently undercharged
(evidenced by inability to crank the engine) at the normal
5-37. BATTERY SPECIFIC GRAVITY TEST. Specific
setting, increase the voltage setting 0.3 volt and check
for improved condition over a reasonable service period.
gravity testing of the battery electrolyte determines the
If necessary, repeat this process until the battery
state of charge in each battery cell. Use a hydrometer
remains charged with a minimum use of water.
and thermometer, correcting the hydrometer reading for
temperature. A corrected specific gravity reading of
2. Batteries which do not respond to the voltage
1.260 to 1.280 in each cell indicates a fully charged
settings within the specified range of this regulator
battery. A specific gravity reading of 1.2220 or less in
usually will be found to be batteries used in vehicles that
each cell indicates that the battery must be recharged or
are operated consistently at low speeds or that have
added electrical loads to the original electrical system, or
replaced.
batteries that have been improperly activated.
NOTE
a. When a vehicle is operated consistently at low
speed and/or electrical loads have been added to the
A temperature corrected specific
original electrical system, the battery may remain
gravity measurement is obtained by
undercharged even with the regulator placed in its
adding
0.004
to
the
actual
maximum setting. Under these conditions, alternator
output or charging time may be insufficient to offset the
hydrometer reading for each 10
electrical load on the battery. Periodic recharging of the
degrees F the electrolyte is above 80
battery from an outside source of replacement of the
degrees F, or subtracting 0.004 from
original alternator with a special extra-output alternator
the actual hydrometer reading for
will be required in these cases.
each 10 degrees F the electrolyte is
below 80 degrees F.
b. Replacement batteries suspected of having
been improperly activated should be removed for a
complete check. If the specific gravity at full charge is
5-38. BATTERY CLEANING. The top of the battery
less than 1.230 in any cell, the battery has either been
must be kept clean. Tighten vent plugs and clean
improperly activated or is worn out and, in either case,
battery with a brush dipped in a solution of baking soda
will give poor performance. If the specific gravity is
and water, followed by a thorough rinse with clear water.
above 1.310 in any cell, the battery has either been filled
If terminals and cable clamps are corroded, disconnect
with electrolyte of too high specific gravity or electrolyte
cables and clean in same manner as battery.
has been added in place of water. Either situation is
harmful to the battery and will cause early failure.