b . I n s t a l l a t i o n . Refer to figure 4-22 and install
4-38.
Belt
Adjusting
Control,
Spring
and
the belt adjusting control, spring and bracket
Bracket Pulley
pulley.
a . Removal. Refer to figure 4-22 and remove the
b e l t adjusting control, spring and bracket pulley.
Section
XIII.
ELECTRICAL
SYSTEM
half throttle and disconnect the field jumper. If the
General
output remains high, the fault is in the generator. If
This section contains information on the main-
the output drops to zero, the fault is in the
tenance
of
the
electrical
system
which
is
the
regulator. Replace a defective generator and/or
responsibility of organizational maintenance.
regulator.
WARNING
(3) When a low-or no-charging rate with
Before
disconnecting  any
electrical
p a r t i a l l y or fully discharged batteries is indicated,
components, make sure battery cables
i n s p e c t for loose connections or damaged wiring. If
are disconnected at batteries to prevent
none, stop the engine and disconnect the field
a serious burn or shock to personnel or
jumper.
Momentarily  connect  a  jumper  wire
damage to equipment.
between the generator  field terminal and the
Engine
Generator
and
Bracket
positive terminal of batteries to polarize the
a.
On-Equipment
Testing.
generator. Reconnect the field jumper and start the
( 1 ) Refer to figure 4-23, and install a suitable
engine. If the charging rate does not increase as the
a d a p t e r in the generator receptacle.
engine speed is increased, slow the engine and
(2) When a high-charging rate with fully-
c o n n e c t a jumper wire between the armature and
c h a r g e batteries is indicated, operate the unit at
field terminals. If the charging rate does not in-