LUBRICATION ORDER
LO 10-3930-643-12
S/N 2001 AND ABOVE
Each brake circuit has its own
pressure converter. Each pressure
Dry cleaning solvent (P-D-680),
converter hydraulic cylinder is
used for cleaning parts, is
supplied by one remotely mounted
toxic and flammable. Use only
brake reservoir. The reservoirs are
in well ventilated areas. Wear
located on the inside of the front
protective goggles and gloves.
frame, on the left and right sides
Do not smoke or allow open
of the forklift.
flames or sparks in areas where
cleaning solvent is used or
NOTE
with
contact
Avoid
stored.
eyes, skin or clothing. If
Right and left reservoirs are
contact with eyes is made,
checked in the same manner.
flush with cold water and seek
medical attention immediately.
Remove the front side access covers.
If contact with skin or cloth-
Clean the reservoir cover
(25).
ing is made, flush with cold
Swing the lockstrap (26) off the
If you become dizzy
water.
cover (25). Remove the cover and
while using cleaning solvent,
Remove
the
breather
assembly.
get fresh air immediately.
diaphragm (27). If fluid is below
the fluid level line, fill the
Unscrew breather plug (29) from
reservoir (28) as necessary, using
Clean
with
breather
assembly.
silicone base brake fluid. Install
P-D-680.
the diaphragm (27).
(29)
into
Screw breather plug
breather assembly. Place cover (25)
and breather assembly on reservoir
(28) and swing lockstrap (26) up to
secure.
Card 12 of 17
|