NOTES - CONTINUED:
12. UNIVERSAL JOINT. Each 500 hours, remove joint,
disassemble, clean and inspect, replace damaged or
worn parts, pack bearings, and assemble.
13. DIFFERENTIAL. Check level each 250 hours.
Change gear lubricant only when required by
maintenance repair action, contamination by water or
other foreign material. After refill, operate for five
minutes, check for leaks and bring oil level to fill and level
plug opening.
14. LUBRICANTS. The following is a list of lubricants
with military symbols and applicable specification
numbers.
OE/HDO
MIL-L-2104
GO
MIL-L-2105
GAA
MIL-G-10924
OEA
MIL-L-46167
BFS
MIL-B-46176
(SD), Type II
P-D-680
Copy of this Lubrication Order will remain
with the equipment at all times, instruc-
tions contained herein are mandatory.
By order of the Secretary of the Army:
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25A,
Operator and Organizational maintenance
requirements for Fork Lifts.
TA 220170
LO 10-3930-624-12
*US. GOVERNMENT PRINTING OFFICE: 1984-420-903/231 CARD 7 OF 7
|