(50) At left-front of inner boom (9),
connect connector (10) of
autoleveler cable (11) on
connector (12) of boom
electrical box (13).
NOTE
Install tie wraps as necessary.
(51) Connect two connectors (5) of
boom wiring harness (6) on
two connectors (7) of boom
floodlight (8).
(52) Start engine (TM 10-3930-673-
10). Raise boom to horizontal
and extend carriage tilt
cylinder.
(53) Partially extend attachment cylinder. Stop engine (TM 10-3930-673-10).