TM 10-3930-673-34
16-5. ATTACHMENT CONTROL VALVE REPAIR (CONT)
NOTE
12
10
Valve section closest to outlet
13
housing has no shuttle plate.
5
16
6
17
(g)
Install four pistons (17),
springs (16), and three shuttle
15
11
plates (15) in each face of
6
housings (1 through 4).
14
7
(h)
Install one preformed packing (13)
and two preformed packings (14) in
each face of housings (1 through 4).
4
(i)
If removed, install plugs (11 and 12)
7
in outlet housing (10).
3
8
9
2
(j)
Match marks on housing sections (1
1
through 4), inlet housing (5), and
TR00747
outlet housing (10) and assemble
them in proper order on stud (8) and
two studs (9). Install nuts (6 and 7).
(k)
Install two nuts (6) and four nuts (7) on stud (8) and two studs (9). Tighten nuts (6) to 33 lb-ft
(44.74 Nm) and nuts (7) to 14 lb-ft (18.98 Nm).
(2)
Assemble relief valves (1 and 2) with parts (2 through 14).
NOTE
Follow-on Maintenance: Install attachment control valve (TM 10-3930-673-20).
END OF TASK
16-24
|