TM 10-3930-673-34
(12)
Install STE/ICE diagnostic
receptacle (10) and resistor
module (11) in cab.
(a)
Position STE/ICE diagnostic
receptacle (10) and resistor
module (11) in cab console (18).
(b)
Install resistor module (11),
screws (15), lockwashers (17), and
nuts (16) in cab console (18).
TR01785
(c)
Install STE/ICE diagnostic
receptacle (10), screws (12),
lockwashers (14), and nuts (13) in
cab.
(13)
Connect ground cable (6) and wiring
connector (5) to vehicle (7) stud.
TR00004
Install wiring connector (5), ground
cable (6), washer (9), and nut (8) to
vehicle (7) stud.
18
11
(14)
Connect STE/ICE shunt
15
(TM 10-3930-673-20).
10
16
17
12
14
13
TR01786
14-13
|