Click here to make tpub.com your Home Page

Page Title: ELECTRIC JOYSTICK ASSEMBLY REPAIR/TEST/ADJUSTMENT - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-34
(h)
If reading in Step (g) was not within limits of 600 to 640 ma., adjust "max out" control (41) and
repeat Step (g) until multimeter reads approximately 620 ma.
(i)
Turn starter switch off (TM 10-3930-673-10).
(j)
Disconnect leads of multimeter. Secure electrical lead #55 to terminal A of lower circuit
board (37) with screw (38).
(k)
Loosen screw (42) at terminal B of lower circuit board (37) and disconnect electrical lead #56.
(l)
Connect positive (+) lead of multimeter to terminal B of lower circuit board (37).
(m) Connect negative () lead of multimeter to disconnected electrical lead #56.
(n)
Turn starter switch to the RUN position but do not start the engine (TM 10-3930-673-10).
(o)
Move joystick handle (5) forward until indicator light (43) just comes on. Multimeter reading
should be between 300 and 340 ma.
NOTE
During Step (p), Turn "threshold" control counterclockwise to lower multimeter reading,
and clockwise to raise multimeter reading.
(p)
If reading in Step (o) was not within limits of 300 to 340 ma., adjust "threshold" control (40)
and repeat Step (o) until multimeter reads approximately 320 ma.
(q)
Move joystick handle (5) fully forward and observe multimeter reading. Reading should be
between 600 and 640 ma.
NOTE
During Step (r), turn "max out" control counterclockwise to lower multimeter reading,
and clockwise to raise multimeter reading.
(r)
If reading in Step (q) was not within limits of 600 to 640 ma., adjust "max out" control (41) and
repeat Step (q) until multimeter reads approximately 620 ma.
(s)
Turn starter switch off (TM 10-3930-673-10).
(t)
Disconnect leads of multimeter. Secure electrical lead #56 to terminal B of lower circuit board
(37) with screw (42).
(u)
Repeat Steps (a) through (k) and check that current readings are still within limits. Readjust
"threshold" (40) and "max out" (41) controls as required.
6-35

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business