TM 10-3930-673-20-2
19-3. AIR CLEANER RESTRICTION INDICATOR REPLACEMENT (CONT)
b. Installation.
4
11
3
7
2
10
1
6
9
8
5
TR00845
(1)
Install three elbows (2, 4 and 5) on frame (7) and air cleaner (5).
(2)
Connect tube (3) on two elbows (4 and 5).
(a)
Install tube (3) on elbow (4) in air cleaner (6).
(b)
Install tube (3) on elbow (5) in frame (7).
(c)
Position two clamps (10) on tube (3) and install on screws (11) with two lockwashers (9) and nuts (8).
(3)
Install air cleaner restriction indicator (1) in elbow (2).
END OF TASK