CAUTION
Wipe area clean around all hydraulic connections to be opened during removal and disassembly. Cap
oil hoses and plug holes. Contamination of hydraulic system could result in equipment failure.
NOTE
Use suitable container to catch any hydraulic oil that may drain from system.
(3)
Tag, mark, and remove 12 hydraulic hoses (10 through 21) from fittings (22 through 32).
(a)
Tag, mark, and remove three hoses (10 through 12) from tees (22 and 23).
(b)
Tag, mark, and remove two hoses (13 and 14) from elbow (24) and adapter (25).
(c)
Tag, mark, and remove two hoses (15 and 16) from adapters (26 and 27).
(d)
Tag, mark, and remove two hoses (17 and 18) from adapters (28 and 29).
(e)
Tag, mark, and remove two hoses (19 and 20) from adapters (30 and 31).
(f)
Tag, mark, and remove hose (21) from adapter (32).
18-37