TM 10-3930-673-20-2
(3)
Remove mounting hardware (parts 50
52
53
through 52) and main control valve (49) from
compartment wall (53).
51
50
CAUTION
Main control valve weighs 60 lb (27.22
kg). When removing, support valve so
valve does not drop.
Remove three nuts (50), lockwashers (51),
screws (52), and main control valve (49) from
49
compartment wall (53). Discard lockwashers.
b. Installation.
TR01838
(1)
Install main control valve (49) on
compartment wall (53) with mounting
hardware (parts 50 through 52).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water.
(a)
Apply sealing compound to threads of three screws (52).
(b)
Position screw (52) through compartment wall (53) and flange of main control valve (49). Position
lockwasher (51) and nut (50) on end of screw. Tighten nut finger tight.
(c)
Install two screws (52), lockwashers (51), and nuts (50). Tighten three nuts (50).
18-23
|