Click here to make tpub.com your Home Page

Page Title: Installation
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-2
8-53. HYDRAULIC BYPASS SWITCH TEST/REPLACEMENT (CONT)
(2)
Remove hydraulic bypass switch (1) from frame (8).
5
2
6
3
7
8
9
4
10
11
12
1
(a)
Remove tube assembly (9) adapter (10), coupling (11), and switch (1) from tee (12) as an assembly.
(b)
Remove hydraulic bypass switch (1) from coupling (11).
(c)
Remove coupling (11) and tube assembly (9) from adapter (10).
c. Installation.
NOTE
Ensure all sealing surfaces on switch and parts are clean and dry.
(1)
Install hydraulic bypass switch (1) on frame (8).
NOTE
To prevent sealant from contaminating the hydraulic system, apply sealant carefully during Steps
(1)(a) and (1)(b) below.
(a)
Apply sealing compound to threads of hydraulic bypass switch (l) and install on coupling (11).
NOTE
During Step (1)(b), apply sealant only to threads of adapter that mate with coupling. Do not apply
sealant to threads that mate with tube assembly.
(b)
Apply sealing compound to threads of adapter (10) and install on coupling (11).
8-176

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business