TM 10-3930-673-20-2
8-50. BOOM ELECTRICAL CABLE TEST/REPAIR/REPLACE (CONT)
(4)
Connect three electrical wires (4) on terminal
strip (5) of auto leveler circuit board (6).
(a)
Position three electrical wires (4) on
terminal strip (5) and tighten screws (7).
4
(b)
Install boom electrical box cover (2) on
boom electrical box (3) with four screws
(1).
3
7
5
2
6
1
TR00372
(5)
Install boom electrical cable (12) on
underside of outer boom (17) with four
17
clamp assemblies (parts 13 through 16).
NOTE
Install clamp assembly closest to pulley
16
first.
(a)
With aid of assistant, continue to hold
boom electrical cable (12) snug and
12
secure cable to underside of outer boom
with eight clamp halves (16), four cover
14
plates (15), eight lockwashers (14) and
15
screws (13).
13
TR00375
8-164
|