TM 10-3930-673-20-2
8-45. AUXILIARY BATTERY CABLES AND TERMINALS SERVICE/REPLACEMENT
(CONT)
(2)
Remove three auxiliary battery cables (4
6
through 6) from two auxiliary batteries (7
15
and 8).
Remove three auxiliary battery cables (4
4
13
5
14
through 6) from two auxiliary batteries (7 and
11
8) as described in Steps (2), (3), and (4) of
b. Removal below.
9
12
(3)
Clean four battery terminals (9 through 12)
and three cable clamps (13 through 15).
(a)
Clean four battery terminals (9 through
12) and three cable clamps (13 through
15) with soda solution and wire brush as
required. Wipe clean with a dry rag.
10
(b)
Apply a light coating of petroleum jelly
7
on battery terminals and cable clamps to
retard corrosion.
8
(4)
Connect three auxiliary battery cables (4
through 6) to two auxiliary batteries (7 and
8).
TR00739
Perform Step (4) of c. Installation below.
(5)
Install auxiliary battery box cover (1) on
auxiliary battery box (2).
3
Position battery box cover (1) on battery box (2)
and hook two rubber hooks (3).
b. Removal.
1
(1)
Remove auxiliary battery box cover (1) from
auxiliary battery box (2).
Unhook two rubber straps (3) and remove
battery box cover (1) from battery box (2).
2
TR00738
8-138
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |