TM 10-3930-673-20-2
b. Removal.
(1)
Disconnect batteries (Para 8-42).
CAUTION
Support cover as required so that weight of cover and circuit board is not supported by electrical wires
to board, or damage to equipment could result.
NOTE
If autoleveler switch and circuit board have been tested, begin removal at Step (3) below.
(2)
Loosen four screws (1) and separate cover (2)
8
7
from boom electrical box (3) to provide
access to fork autoleveler circuit board (4).
3
(3)
Unscrew collar (7) and disconnect
autoleveler cable (8) from connector (9).
9
1
2
4
TR00325
(4)
Remove four screws (10), lockwashers (11),
10
connector (9), and electrical cable (12) from
boom electrical box (3). Discard lockwashers.
9
(5)
Tag and mark four electrical wires (13) on
12
terminal strip (14) of circuit board (4).
(6)
Loosen four screws (15) on terminal strip
13
(14) and remove electrical wires (13).
11
3
15
14
4
8-55
|