TM 10-3930-673-20-2
NOTE
Support starting motor to prevent from dropping
during removal.
(1)
Remove screw (28) and starting motor (3)/
starting motor solenoid (19) from bell
housing (4) as an assembly.
b. Installation.
NOTE
Support starting motor to prevent from
dropping during installation.
Connect wires as shown in wiring diagram on
TR00302
(1)
Install starting motor (3)/starting motor
solenoid (19) on bell housing (4) with screw
(28). Tighten screw to 32 lb-ft (43.4 Nm).
(2)
Install two electrical wires (26 and 27) on
starting motor solenoid (19) with washer (25)
and nut (24).
(3)
Install two electrical wires (22 and 23) on
starting motor solenoid (19) with
lockwasher (21) and nut (20).
(4)
Install two electrical wires (17 and 18) and
positive cable (16) on starting motor
solenoid (19) with starwasher (15) and nut
(14).
(5)
Install electrical wire (12) on auxiliary
positive cable (13) with screw (11) and nut
(10). Tighten screw to 32 lb-ft (43.4 Nm).
Change 1