TM 10-3930-673-20-2
7-3. THERMOSTAT AND WATER OUTLET REPLACEMENT (CONT)
8
6
7
3
2
4
5
TR00295
1
(3)
Install hose (8) on water outlet (3) with clamp (7).
(4)
Install alternator support bracket (2) on water outlet (3) and alternator (1) on support (2).
(a)
Install support bracket (2) on water outlet (3) with three screws (6). Tighten screws to 216 lb-in. (24.4 Nm).
(b)
Align alternator (1) with support bracket (2).
(c)
Install alternator (1) on support bracket (2) with screw (5) and nut (4).
NOTE
Follow-on Maintenance:
Install drive belt to alternator pulley (Para 7-9).
Connect negative battery cable (Para 8-44).
Fill engine cooling system with coolant (Para 7-2).
END OF TASK
7-28
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |