Click here to make tpub.com your Home Page

Page Title: Installation-CONT.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-2
7-3. THERMOSTAT AND WATER OUTLET REPLACEMENT (CONT)
8
6
7
3
2
4
5
TR00295
1
(3)
Install hose (8) on water outlet (3) with clamp (7).
(4)
Install alternator support bracket (2) on water outlet (3) and alternator (1) on support (2).
(a)
Install support bracket (2) on water outlet (3) with three screws (6). Tighten screws to 216 lb-in. (24.4 Nm).
(b)
Align alternator (1) with support bracket (2).
(c)
Install alternator (1) on support bracket (2) with screw (5) and nut (4).
NOTE
Follow-on Maintenance:
Install drive belt to alternator pulley (Para 7-9).
Connect negative battery cable (Para 8-44).
Fill engine cooling system with coolant (Para 7-2).
END OF TASK
7-28

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business