TM 10-3930-673-20-1
Maintenance Allocation Chart for All Terrain Lifter, Army System (ATLAS) (Continued)
(4)
(1)
(2)
(3)
(5)
(6)
Maintenance Level
FIELD
SUSTAINMENT
Unit
DS
GS
Depot
Group
Maintenance
Tools and
Number Component/Assembly
Function
C
O
F
H
D
Equipment Remarks
Radiator Overflow Tank
Replace
0.5
0502
Cover
Replace
2.0
2
0503
Water Manifold, Headers,
Thermostats, Housing
Gasket:
Thermostat
Test
1.0
3
Replace
0.5
2
Housing
Replace
1.0
2
Radiator Hoses
Inspect
0.1
Replace
0.5
2
0504
Water Pump
Replace
2.0
2
0505
Fan Assembly:
Fan Blade and Spacer
Inspect
0.1
Replace
1.5
2
Fan Guard
Inspect
0.1
Replace
1.0
2
Drive Belt and Tensioner
Inspect
0.1
2
Replace
1.5
2
06
ELECTRICAL SYSTEM
0601
Alternator and Alternator
Replace
0.4
2
Connections
Repair
4.0
5
Pulley
Replace
1.0
2
0603
Starter:
Starting Motor
Replace
0.4
2
Repair
4.0
5
Neutral Safety Switch
Inspect
0.2
Replace
0.5
2
0607
Instrument Panel:
Instrument Panel
Replace
4.0
2,3
Gages, Switches, Lights
Inspect
0.1
Replace
0.5
3
Circuit Breakers
Replace
0.2
3
B-8