TM 10-3930-673-20-1
FRAME TILT VALVE
PRESSURE TEST
(1) Remove cover from diagnostic coupler.
(2) Perform STE/ICE Test #51
(TM 9-4910-571-12&P).
(3) Read output pressure on test device.
(a) If hydraulic oil pressure is at 2600
to 2700 psi (17940 to 18630 kPa),
go to Step 7 of this fault.
(b) If hydraulic oil pressure is not at
2600 to 2700 psi (17940 to 18630
kPa), shut down engine (TM 10-
3930-673-10) and replace frame tilt
valve.
FRAME TILT CYLINDER
VISUAL INSPECTION
Visually inspect frame tilt cylinder and its
housing for signs of damage.
(a) If frame tilt cylinder and/or its
housing are not damaged, notify
Direct Support about this fault.
(b) If frame tilt cylinder and/or its
housing are damaged, shut down
engine (TM 10-3930-673-10) and
replace cylinder and/or its housing
(Para 18-13).