TM 10-3930-673-20-1
CONDENSOR
CONDENSER
VISUAL INSPECTION
RADIATOR
Visually inspect condenser fins for dirt and
debris or signs of damage.
(a) If condenser fins are free to radiate
heat and condenser is free from
signs of damage, go to Step 5 of
this fault.
(b) If condenser fins are blocked by
dirt and debris, clean condenser
with water or air (under pressure).
(c) If condenser shows signs of
damage, notify Direct Support
Maintenance.
CONNECTIONS
EVAPORATOR
HEATER
EVAPORATOR
VISUAL INSPECTION
Visually inspect evaporator fins for dirt and
debris, and for signs of damage.
(a) If evaporator fins are clean and
free from damage, go to Step 6 of
this fault.
(b) If evaporator fins obstructed with
TR01477
dirt and debris, clean fins.
(c) If evaporator shows signs of
damage, repair or replace
evaporator.
2-767
|