TM 10-3930-673-20-1
AIR CONDITIONER BELT
VISUAL INSPECTION
Inspect air conditioner belt for proper tension
and/or signs of wear.
(a) If tension correct and belt free from
signs of wear, go to Step 3 of this
fault.
(b) If tension is incorrect, tighten or
loosen the belt as necessary
(Para 7-8).
(c) If belt shows signs of wear (cracks,
deteriorated sections), replace belt
(Para 7-8).
AIR CONDITIONER
B
ELT
PULLEY
C
AIR
LINES AND FITTINGS
C ONDITIONER
VISUAL INSPECTION
OMPRESSOR
Use a leak detector (which is sensitive to
refrigerant in use) to check air conditioning
lines and fittings for leaks.
CONDENSOR
(a) If lines and fittings are clean, tight,
and free from leaks, go to Step 4 of
this fault.
RADIATOR
(b) If leaks are detected, evacuate
system, replace faulty lines and/or
fittings, and recharge system.
TR01476
CONNECTIONS
2-765
|