WARNING
Do not smoke or allow open flame or sparks in the vicinity while working on any part of the fuel system. Diesel fuel is highly
flammable and can cause injury or death if accidentally ignited.
Improper cleaning methods and use of unauthorized cleaning solvents may injure personnel and damage equipment. Refer to
TM9-247 for correct information.
Eye shields must be worn when cleaning with a wire brush. Flying rust and metal particles may cause injury to personnel.
Particles blown by compressed air are hazardous. Make certain the air stream is directed away from user and other personnel in
the area. To prevent injury, user must wear protective goggles or face shield when using compressed air.
CAUTION
Washing oil seals, electrical cables and flexible hoses with dry cleaning solvents or mineral spirits will cause serious damage or
destroy materials.
RESISTANCE TEST AND
DRAW OF SOLENOID
Set multimeter to ohms to test resistance of
fuel shutoff solenoid. Set multimeter to amps
to test draw of solenoid (Para 5-2).
(a) If resistance and draw are within
specified ohms and amperes, go to
Step 2 of this fault.
(b) If resistance and/or draw are not
within specified ohms and
amperes, notify Direct Support to
replace solenoid.
FUEL SHUTOFF SOLENOID
TR01204
2-753