Page Title: ENGINE STARTS BUT DOES NOT CONTINUE TO RUN - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
FUEL FLOW THROUGH FILTER
VISUAL INSPECTION
Check flow of fuel through fuel filter
(Para 5-11).
(a) If fuel flows freely without air, go to
Step 5 of this fault.
(b) If air in fuel lines, check for air
leaks, shut down engine
(TM 10-3930-673-10), and bleed
system (Para 5-11).
FUEL FILTER FUEL
T
PRANSFER
UMP
FILTER AND FUEL
VISUAL INSPECTION
TR01189
Check fuel consistency in fuel filter
(Para 5-15).
(a) If fuel is thin and flows freely, go to
Step 6 of this fault.
(b) If fuel is thick and jelling, shut down
engine (TM 10-3930-673-10),
clean fuel system (Para 5-15) and
replace fuel with climatized fuel
(Para 5-9).
2-631