TM 10-3930-673-20-1
WARNING
Drycleaning solvent P-D-680 (Type II) is a flammable solvent that is potentially dangerous to personnel. Keep away from heat,
sparks, or open flame. Flash point of solvent is 138 degrees F (59 degrees C). Use only in a well-ventilated area. Inhaling vapors
over a period of time can cause headache and drowsiness. Use gloves to prevent irritation or inflammation of the skin. Solvent
absorbed through the skin can result in internal disorders. If contact occurs, wash the affected area with water for 15 minutes. For
eyes, flush with water and then seek immediate medical attention.
Improper cleaning methods and use of unauthorized cleaning solvents may injure personnel and damage equipment. Refer to
TM9-247 for correct information.
Eye shields must be worn when cleaning with a wire brush. Flying rust and metal particles may cause injury to personnel.
Particles blown by compressed air are hazardous. Make certain the air stream is directed away from user and other personnel in
the area. To prevent injury, user must wear protective goggles or face shield when using compressed air.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
CA
Washing oil seals, electrical cables and flexible hoses with dry
cleaning solvents or mineral spirits will cause serious damage or
destroy materials.
COVER
BATTERY TERMINALS AND CABLE
CONNECTIONS VISUAL INSPECTION
CONNECTIONS
Check battery terminals for corrosion, and
check tightness of cable connections.
(a) If battery terminals are clean, and
cable connections properly
tightened, go to Step 2 of this fault.
(b) If terminals are corroded, clean
terminals, If cable connections are
loose, tighten connections. Restart
vehicle.
COVER
CONNECTIONS
TR01446
2-615
|